AutoCAD Architectural Desktop 3.0 ServicePark 2.0
유틸리티
작성자
시삽
작성일
2001-04-23 16:39
조회
2122
AutoCAD Architectural Desktop 3.0 ServicePark 2.0입니다.
영문판용 입니다.
출처 : http://www.autodesk.com
다음은 서비스팩에 대한 설명 원문입니다.
Autodesk Architectural Desktop 3 - Service Pack 2
This update addresses several additional issues with the original shipping
version of ADT R3.
1 The Style Manager no longer has problems with Circular Xref Overlay files.
2 The removal of System Default display properties from Structural Members
will no longer cause an unexpected exit.
3 Changes to the regional number settings will no longer affect the shapes
imported from the Structural Catalog.
4 Stairs with freely anchored railings can now be modified without needing
to detach the railing first.
5 Deleting columns in the Schedule Table Style dialog by picking column
headers and superheaders will no longer cause an exception. The stability
when moving columns has also been improved.
6 The View Blocks for Multi-view Block definitions can now be modified
without affecting the attached Schedule Property Sets.
7 Deleting an area while the Properties Window is displayed will no longer
cause a fatal error.
8 Window Assemblies with window style infill can now be grip edited.
9 Doors and Windows in Curtain Walls and Window Assemblies will now
correctly report their size in Schedule Tables.
10 Rolled-up Add and Modify dialogs can no longer be lost off the right edge
of the screen.
11 Some problems with Live Sections and Structural Members have been
corrected.
12 The Wall Shrinkwrap component will no longer disappear under certain
Interference conditions, and the component lines that are hidden by the
shrinkwrap will now appear when the shrinkwrap layer is turned off.
Issues addressed by Service Pack 1
1 Several functions within ActiveX have been corrected.
2 An occasional crash when creating a roof dormer has been fixed.
3 Control+Grip stretching of Roof Slab edges is more stable.
4 Copy and paste of Curtain Walls and Window Assembly between drawings (which have
incompatible styles of the same name) has been resolved.
5 It is no longer possible that ADT will "hang" when pressing a key in a grid
control (which is used in the Display Manager, Wall and Curtain Wall Cutplane
table, the Style Manager when the view is toggled to a style-sorted view,
2D Section Styles Components and Design Rules tab, Structural Styles Design Rules
tab, Stair Styles Stringer tab and Railing Styles Components tab).
6 The ARRAY command will now work correctly after Preview / Modify.
7 Some problems opening drawings from previous versions of ADT have been resolved.
8 Several problems with the original templates and content have been resolved.
In particular, the default Window Tag will now increment, as in ADT R2. In
addition, the Space Tags have been corrected to read a property set that is
attached to the Space Style. This property set has been attached to all Space
Styles in the Aec templates, but if you create a drawing from scratch, add and
tag a Standard space, the tag will not display properly until the Space Style
property set it attached to the Space Style.
9 You can now select any number of lines in the 2D Section "Edit Linework" command.
10 Structural members will now display the Plan representation Axis component
properly.
11 Mitering of Wall Sweep Profiles has been improved.
12 There is no longer the possibility of a problem when inserting a drawing
containing AEC Dimensions into another drawing, no matter how the second drawing
is started, or how the insert is accomplished.
13 Areas and Area Group objects now use the units specified in the Drawing Setup
dialog, so it is no longer necessary to use a Calculation Modifier to obtain
results in Square Feet when working in Imperial drawings.
In addition, there are a few new Known Issues that should be noted.
Default Layer Key Style
Problem: When you apply this patch, your default layer key style will be set to
AIA (256 color). Note that this will affect only new drawings that you create.
Workaround: Start a new drawing, go to the Layering tab of Drawing Setup
(Desktop > Layer Management > Select Layer Standard...). Pick the desired Layer
Key Style from the drop list, check the option "Save as Default", and pick OK.
Opening Drawings with LDDT Objects in ADT3
If you encounter difficulty opening drawings that contain objects from LDDT, you
should be sure to upgrade to the latest LDDT service pack or Civil object enabler.
Layer 0
If layer 0 is frozen, all Multi-view Blocks will no longer be displayed (note that
Schedule tags and Column Grid bubbles are Multi-view Blocks). Similarly, any
custom display block used by an object (Door, Window, Curtain Wall, Window
Assembly, Railing, Structural Member) will no longer appear. In addition, the
contents of Schedule Tables will disappear.
Aec Dimension of Openings Adjacent to Intersecting Wall
Problem: If you have a wall which contains openings, doors or windows that are
immediately adjacent to an intersecting wall, you may have incorrect dimensions
reported. The openings may be combined into a single dimension, or the heights
for the openings may appear in the wrong location.
Workaround: Move the windows a minute distance, such as 0.0001 meters, away
from the intersecting wall.
Design Center - Miscellaneous Documentation
Problem: Fire Rating Lines will be drawn along the Wall Graph Line, so if wall
cleanup is NOT calculated at the center line (Options > AEC DwgDefaults >
"Use Center Line as Graph Line"), the rating line will be drawn at the
justification position of the wall. This could be the right or left edge,
or baseline of the wall style.
Workaround: Because the line that results from this command is a polyline,
you can use the offset command to correct the position of the fire rating line.
For example, if the walls are 8" wide and are justified either to right or left,
you will need to offset the fire rating polyline by 4". In some cases, you will
need to break the polyline to offset segments in different directions.
XRef Bind
If you encounter a drawing that will not Xref Bind, or in which objects
disappear after Xref Bind, you have two options:
1 Attach the drawing as a block and explode it. This is the simpler option,
but will behave like the Insert type of bind, so layer and other symbol
names will not have the Xref file name attached to them.
2 The failure may be due to an object which uses a custom block that contains
the same object type. For example, if you have a window style that uses a
window of a different style as a custom block, the resulting file will not
bind. The precise solution is to explode the object which is being used as
the custom block to primitive objects (line, arc, 3D face, etc.), then
create a new block of that object. This non-ADT object block can be used
without difficulty.
Walls on Locked Layers
Walls on Locked Layers will not clean up properly. You must unlock the wall
layer and use the ObjRelUpdate command to restore the proper appearance.
Wall Shrinkwrap
If you edit the floorline or roofline of a wall, the shrinkwrap component in
the plan representation will not be appropriately truncated if the floorline
is above or the roofline is below the specified cut height. Using the
setting "Do True Cut" will not properly represent the Shrink Wrap component;
it will still enclose the entire wall. If the above or below cut height
components are displayed, they may conceal the shrink wrap component on
screen, but it will still be plotted incorrectly. The wall's individual
component boundaries will be properly displayed, and will serve to represent
a single component wall properly. In the case of multiple component walls,
a mass element can be used as a subtractive body modifier to change the
wall's shape. The shrinkwrap will be properly drawn in this case.
Exporting Architectural Desktop Release 3 Drawings
If you open an R3 drawing directly in R2i, the "Future Version" warning will
appear for every ADT drawing opened until you exit ADT2i and re-start.
Curtain Wall Reference
The section "Creating a Curtain Wall that References a Curve" (under Curtain
Walls > Creating Curtain Walls or page 243 of the User's Guide) states that
you can use Any AEC Object as the reference. In fact, you cannot use Stairs
or Multi-view Blocks as the reference for a Curtain Wall.
영문판용 입니다.
출처 : http://www.autodesk.com
다음은 서비스팩에 대한 설명 원문입니다.
Autodesk Architectural Desktop 3 - Service Pack 2
This update addresses several additional issues with the original shipping
version of ADT R3.
1 The Style Manager no longer has problems with Circular Xref Overlay files.
2 The removal of System Default display properties from Structural Members
will no longer cause an unexpected exit.
3 Changes to the regional number settings will no longer affect the shapes
imported from the Structural Catalog.
4 Stairs with freely anchored railings can now be modified without needing
to detach the railing first.
5 Deleting columns in the Schedule Table Style dialog by picking column
headers and superheaders will no longer cause an exception. The stability
when moving columns has also been improved.
6 The View Blocks for Multi-view Block definitions can now be modified
without affecting the attached Schedule Property Sets.
7 Deleting an area while the Properties Window is displayed will no longer
cause a fatal error.
8 Window Assemblies with window style infill can now be grip edited.
9 Doors and Windows in Curtain Walls and Window Assemblies will now
correctly report their size in Schedule Tables.
10 Rolled-up Add and Modify dialogs can no longer be lost off the right edge
of the screen.
11 Some problems with Live Sections and Structural Members have been
corrected.
12 The Wall Shrinkwrap component will no longer disappear under certain
Interference conditions, and the component lines that are hidden by the
shrinkwrap will now appear when the shrinkwrap layer is turned off.
Issues addressed by Service Pack 1
1 Several functions within ActiveX have been corrected.
2 An occasional crash when creating a roof dormer has been fixed.
3 Control+Grip stretching of Roof Slab edges is more stable.
4 Copy and paste of Curtain Walls and Window Assembly between drawings (which have
incompatible styles of the same name) has been resolved.
5 It is no longer possible that ADT will "hang" when pressing a key in a grid
control (which is used in the Display Manager, Wall and Curtain Wall Cutplane
table, the Style Manager when the view is toggled to a style-sorted view,
2D Section Styles Components and Design Rules tab, Structural Styles Design Rules
tab, Stair Styles Stringer tab and Railing Styles Components tab).
6 The ARRAY command will now work correctly after Preview / Modify.
7 Some problems opening drawings from previous versions of ADT have been resolved.
8 Several problems with the original templates and content have been resolved.
In particular, the default Window Tag will now increment, as in ADT R2. In
addition, the Space Tags have been corrected to read a property set that is
attached to the Space Style. This property set has been attached to all Space
Styles in the Aec templates, but if you create a drawing from scratch, add and
tag a Standard space, the tag will not display properly until the Space Style
property set it attached to the Space Style.
9 You can now select any number of lines in the 2D Section "Edit Linework" command.
10 Structural members will now display the Plan representation Axis component
properly.
11 Mitering of Wall Sweep Profiles has been improved.
12 There is no longer the possibility of a problem when inserting a drawing
containing AEC Dimensions into another drawing, no matter how the second drawing
is started, or how the insert is accomplished.
13 Areas and Area Group objects now use the units specified in the Drawing Setup
dialog, so it is no longer necessary to use a Calculation Modifier to obtain
results in Square Feet when working in Imperial drawings.
In addition, there are a few new Known Issues that should be noted.
Default Layer Key Style
Problem: When you apply this patch, your default layer key style will be set to
AIA (256 color). Note that this will affect only new drawings that you create.
Workaround: Start a new drawing, go to the Layering tab of Drawing Setup
(Desktop > Layer Management > Select Layer Standard...). Pick the desired Layer
Key Style from the drop list, check the option "Save as Default", and pick OK.
Opening Drawings with LDDT Objects in ADT3
If you encounter difficulty opening drawings that contain objects from LDDT, you
should be sure to upgrade to the latest LDDT service pack or Civil object enabler.
Layer 0
If layer 0 is frozen, all Multi-view Blocks will no longer be displayed (note that
Schedule tags and Column Grid bubbles are Multi-view Blocks). Similarly, any
custom display block used by an object (Door, Window, Curtain Wall, Window
Assembly, Railing, Structural Member) will no longer appear. In addition, the
contents of Schedule Tables will disappear.
Aec Dimension of Openings Adjacent to Intersecting Wall
Problem: If you have a wall which contains openings, doors or windows that are
immediately adjacent to an intersecting wall, you may have incorrect dimensions
reported. The openings may be combined into a single dimension, or the heights
for the openings may appear in the wrong location.
Workaround: Move the windows a minute distance, such as 0.0001 meters, away
from the intersecting wall.
Design Center - Miscellaneous Documentation
Problem: Fire Rating Lines will be drawn along the Wall Graph Line, so if wall
cleanup is NOT calculated at the center line (Options > AEC DwgDefaults >
"Use Center Line as Graph Line"), the rating line will be drawn at the
justification position of the wall. This could be the right or left edge,
or baseline of the wall style.
Workaround: Because the line that results from this command is a polyline,
you can use the offset command to correct the position of the fire rating line.
For example, if the walls are 8" wide and are justified either to right or left,
you will need to offset the fire rating polyline by 4". In some cases, you will
need to break the polyline to offset segments in different directions.
XRef Bind
If you encounter a drawing that will not Xref Bind, or in which objects
disappear after Xref Bind, you have two options:
1 Attach the drawing as a block and explode it. This is the simpler option,
but will behave like the Insert type of bind, so layer and other symbol
names will not have the Xref file name attached to them.
2 The failure may be due to an object which uses a custom block that contains
the same object type. For example, if you have a window style that uses a
window of a different style as a custom block, the resulting file will not
bind. The precise solution is to explode the object which is being used as
the custom block to primitive objects (line, arc, 3D face, etc.), then
create a new block of that object. This non-ADT object block can be used
without difficulty.
Walls on Locked Layers
Walls on Locked Layers will not clean up properly. You must unlock the wall
layer and use the ObjRelUpdate command to restore the proper appearance.
Wall Shrinkwrap
If you edit the floorline or roofline of a wall, the shrinkwrap component in
the plan representation will not be appropriately truncated if the floorline
is above or the roofline is below the specified cut height. Using the
setting "Do True Cut" will not properly represent the Shrink Wrap component;
it will still enclose the entire wall. If the above or below cut height
components are displayed, they may conceal the shrink wrap component on
screen, but it will still be plotted incorrectly. The wall's individual
component boundaries will be properly displayed, and will serve to represent
a single component wall properly. In the case of multiple component walls,
a mass element can be used as a subtractive body modifier to change the
wall's shape. The shrinkwrap will be properly drawn in this case.
Exporting Architectural Desktop Release 3 Drawings
If you open an R3 drawing directly in R2i, the "Future Version" warning will
appear for every ADT drawing opened until you exit ADT2i and re-start.
Curtain Wall Reference
The section "Creating a Curtain Wall that References a Curve" (under Curtain
Walls > Creating Curtain Walls or page 243 of the User's Guide) states that
you can use Any AEC Object as the reference. In fact, you cannot use Stairs
or Multi-view Blocks as the reference for a Curtain Wall.
전체 0
댓글을 남기려면 로그인하세요.
유틸리티
번호 | 제목 | 작성자 | 작성일 | 조회 |
공지사항 |
[공지] 글꼴은행 - 캐드 글꼴 442종 압축 파일 NOTICE
gocad
|
2022.09.01
|
조회 22967
|
gocad | 2022.09.01 | 22967 |
30 |
저한테 새한글폰트가 있네요
백좁니다
|
2001.05.04
|
조회 1005
|
백좁니다 | 2001.05.04 | 1005 |
29 |
이런폰트는 올려주실수 없나요? (3)
김영수
|
2001.05.03
|
조회 777
|
김영수 | 2001.05.03 | 777 |
28 |
find.lsp
빌린인생
|
2001.04.26
|
조회 2163
|
빌린인생 | 2001.04.26 | 2163 |
27 |
x.lsp (2)
빌린인생
|
2001.04.26
|
조회 3533
|
빌린인생 | 2001.04.26 | 3533 |
26 |
캐드메뉴얼좀... (4)
이동훈
|
2001.04.26
|
조회 818
|
이동훈 | 2001.04.26 | 818 |
25 |
AutoCAD Architectural Desktop 3.0 ServicePark 2.0
시삽
|
2001.04.23
|
조회 2122
|
시삽 | 2001.04.23 | 2122 |
24 |
폰트구함. winmark.shx (2)
원대중
|
2001.04.17
|
조회 2346
|
원대중 | 2001.04.17 | 2346 |
23 |
한번에 purge 를 4번 할는 리습.. (2)
빌린인생
|
2001.04.07
|
조회 1834
|
빌린인생 | 2001.04.07 | 1834 |
22 |
폰트 구합니다....sgd...... (2)
이재균
|
2001.04.06
|
조회 624
|
이재균 | 2001.04.06 | 624 |
21 |
제가 캐드를 장만햇거든여 그런데 실수로 cd 키를 이저먹엇어여 갈겨주세요 (1)
오승엽
|
2001.04.04
|
조회 579
|
오승엽 | 2001.04.04 | 579 |
20 |
조기여~ 급해여 r12... (2)
빼로
|
2001.04.03
|
조회 742
|
빼로 | 2001.04.03 | 742 |
19 |
Ghs.shx (1)
빌린인생
|
2001.03.31
|
조회 1202
|
빌린인생 | 2001.03.31 | 1202 |
18 |
AutoCAD R14.00을 R14.01로 업데이트 합니다. (1)
시삽
|
2001.03.23
|
조회 1641
|
시삽 | 2001.03.23 | 1641 |
17 |
AutoCAD용 참한글 폰트 (1)
시삽
|
2001.03.15
|
조회 2211
|
시삽 | 2001.03.15 | 2211 |
16 |
AutoCAD용 진한글 폰트 (2)
시삽
|
2001.03.15
|
조회 2093
|
시삽 | 2001.03.15 | 2093 |
15 |
슬라이드 라이브러리 작성 유틸리티 (1)
시삽
|
2001.03.14
|
조회 2244
|
시삽 | 2001.03.14 | 2244 |
14 |
AutoCAD 기본 한글폰트 4개 (2)
시삽
|
2001.03.10
|
조회 2034
|
시삽 | 2001.03.10 | 2034 |
13 |
text또는 dtext로 입력된 숫자를 사칙연산할 수 있는 LISP
시삽
|
2001.02.26
|
조회 2075
|
시삽 | 2001.02.26 | 2075 |
12 |
한글판 AutoCAD 2000i(아이) 전용 서비스팩 #2
시삽
|
2001.02.13
|
조회 2267
|
시삽 | 2001.02.13 | 2267 |
11 |
한글폴더의 도면을 츨력할때 애러 해결 [AutoCAD 2000전용]
시삽
|
2001.02.11
|
조회 1593
|
시삽 | 2001.02.11 | 1593 |